Carregant...
Carregant...

Vés al contingut (premeu Retorn)

Evaluation of an automated luminescent bacteria assay for in situ aquatic toxicity determination

Autor
López, R.; Kazlauskaite, L.; Ribó, J.; Riva, M.; González, S.; Cortina, J.
Tipus d'activitat
Article en revista
Revista
Science of the total environment
Data de publicació
2012-12-01
Volum
440
Pàgina inicial
307
Pàgina final
313
DOI
https://doi.org/10.1016/j.scitotenv.2012.05.043 Obrir en finestra nova
Repositori
http://hdl.handle.net/2117/19650 Obrir en finestra nova
Resum
A new system for monitoring toxicity TOXcontrol® (MicroLAN BV, The Netherlands) has been used to assess the toxicity of a selection of priority or emergent compounds in the laboratory. In this study, inhibition curves and EC50 – Effective Concentration causing 50% inhibition – of selected compounds (including pesticides, pharmaceuticals, surfactants and metals commonly detected in surface or drinking waters) were determined. This new technology is based on the measurement of Vibrio fischeri...
Citació
López, R. [et al.]. Evaluation of an automated luminescent bacteria assay for in situ aquatic toxicity determination. "Science of the total environment", 01 Desembre 2012, vol. 440, p. 307-313.
Paraules clau
Aquatic toxicity, Bioluminescence, On-line toxicity monitoring, Vibrio fischeri, Water quality
Grup de recerca
CRnE - Centre de Recerca en Ciència i Enginyeria Multiescala de Barcelona
INNOTEX CENTER
R2EM - Resource Recovery and Environmental Management
TMAS (T+) - Toxicologia i Microbiologia Ambiental i Sanitària

Participants