A back-emf based method to detect magnet failures in PMSMs

Autor
Urresty, J.; Riba, J.; Romeral, L.
Tipus d'activitat
Article en revista
Revista
IEEE transactions on magnetics
Data de publicació
2013
Volum
49
Número
1
Pàgina inicial
591
Pàgina final
598
DOI
https://doi.org/10.1109/TMAG.2012.2207731 Obrir en finestra nova
Resum
Demagnetization faults are troublesome because they have a profound impact on the overall performance of permanent magnet synchronous motors (PMSMs). This work presents and veri¿es experimentally a system to detect such faults which is based on the measure of the zero sequence voltage component (ZSVC). The proposed method is also appropriate for inverter fed machines and is particularly useful when dealing with fault tolerant systems. A fault severity index which allows quantifying the harshnes...