Carregant...
Carregant...

Vés al contingut (premeu Retorn)

Removal of radionuclides in drinking water by membrane treatment using ultrafiltration, reverse osmosis and electrodialysis reversal

Autor
Montaña, M.; Camacho, A.; Serrano, I.; Devesa, R.; Matia, L.; Valles, I.
Tipus d'activitat
Article en revista
Revista
Journal of environmental radioactivity
Data de publicació
2013-11
Volum
125
Pàgina inicial
86
Pàgina final
92
DOI
https://doi.org/10.1016/j.jenvrad.2013.01.010 Obrir en finestra nova
Repositori
http://hdl.handle.net/2117/20668 Obrir en finestra nova
Resum
A pilot plant had been built to test the behaviour of ultra fi ltration (UF), reverse osmosis (RO), and electrodialysis reversal (EDR) in order to improve the quality of the water supplied to Barcelona met- ropolitan area from the Llobregat River. This paper presents results from two studies to reduce natural radioactivity. The results from the pilot plant with four different scenarios were used to design the full- scale treatment plant built (SJD WTP). The samples taken at different steps of th...
Citació
Montaña, M. [et al.]. Removal of radionuclides in drinking water by membrane treatment using ultrafiltration, reverse osmosis and electrodialysis reversal. "Journal of environmental radioactivity", Novembre 2013, vol. 125, p. 86-92.
Paraules clau
Dialysis membranes, Electrodialysis, Pilot plants, Radiology, Radiometry, Reverse osmosis, Ultrafiltration, Uranium, Water quality
Grup de recerca
CRnE - Centre de Recerca en Ciència i Enginyeria Multiescala de Barcelona
DRM - Dosimetria i Radiofísica Mèdica

Participants