Pilot plant comparison study of two commercial nanofiltration membranes in a drinking water treatment plant

Autor
Ribera, G.; Llenas, L.; Rovira, M.; De Pablo, J.; Martinez, X.
Tipus d'activitat
Article en revista
Revista
Desalination and water treatment
Data de publicació
2012-08-06
Volum
51
Número
1-3
Pàgina inicial
448
Pàgina final
457
DOI
https://doi.org/10.1080/19443994.2012.714528 Obrir en finestra nova
Repositori
http://hdl.handle.net/2117/18999 Obrir en finestra nova
URL
http://www.tandfonline.com/doi/abs/10.1080/19443994.2012.714528 Obrir en finestra nova
Resum
A wide range of commercial membranes were tested and compared at laboratory scale in order to select the most appropriate for improving the final water quality of a real drinking water treatment plant (DWTP). Most of the membranes tested showed a reduction of trihalomethanes formation potential (THMFP) higher than 90%. In this work, several NF membranes were tested at laboratory scale in order to evaluate the most suitable NF membrane to reduce THMFP. NF270 (Dow Chemical) and ESNA1LF2 (Hydranaut...
Citació
Ribera, G. [et al.]. Pilot plant comparison study of two commercial nanofiltration membranes in a drinking water treatment plant. "Desalination and water treatment", 06 Agost 2012, vol. 51, núm. 1-3, p. 448-457.
Paraules clau
Drinking water, ESNA1LF2, NF270, Nanofiltration, Pilot plant, Spiral-wound modules, Trihalomethane formation potential
Grup de recerca
CRnE - Centre de Recerca en Ciència i Enginyeria Multiescala de Barcelona
R2EM - Resource Recovery and Environmental Management

Participants

  • Ribera, Gemma  (autor)
  • Llenas Argelaguet, Laia  (autor)
  • Rovira Boixaderas, Miquel  (autor)
  • Pablo Ribas, Joan de  (autor)
  • Martínez Lladó, Xavier  (autor)