Carregant...
Carregant...

Vés al contingut (premeu Retorn)

Distortional buckling test for steel storage rack columns

Autor
Casafont, M.; Roure, F.; Pastor, M.M.; Bonada, J.; Peköz, T.
Tipus d'activitat
Article en revista
Revista
Proceedings of the Institution of Civil Engineers. Structures and buildings
Data de publicació
2013-09
Volum
166
Número
8
Pàgina inicial
392
Pàgina final
402
DOI
https://doi.org/10.1680/stbu.12.00055 Obrir en finestra nova
URL
http://www.icevirtuallibrary.com/content/article/10.1680/stbu.12.00055 Obrir en finestra nova
Resum
An investigation into the test method for distortional buckling of steel storage rack columns is presented. The main problem of the experimental method is to determine the length of the samples to be tested. The paper proposes to solve this problem by performing linear buckling analysis of the columns. Nowadays, linear buckling analysis can be easily carried out by practical designers with the help of newly developed programs based on the finite strip method and generalised beam theory. A simple...
Paraules clau
columns, design methods & aids, steel structures
Grup de recerca
REMM - Recerca en Estructures i Mecànica de Materials

Participants