Carregant...
Carregant...

Vés al contingut (premeu Retorn)

Outage Key Safety Functions Configuration risk assessment for a three loops Westinghouse PWR

Autor
Martínez Cid, M.; Dies, J.; Tapia, C.; Diaz, P.
Tipus d'activitat
Article en revista
Revista
Nuclear engineering and design
Data de publicació
2015-09-01
Volum
291
Pàgina inicial
271
Pàgina final
276
DOI
https://doi.org/10.1016/j.nucengdes.2015.05.024 Obrir en finestra nova
Repositori
http://hdl.handle.net/2117/84978 Obrir en finestra nova
Resum
The methodology developed provides guidance on the use of Probabilistic Safety Assessment (PSA) for the risk-informed evaluation of Guides which ensure the compliment of Outage Key Safety Functions (OKSFs) in Nuclear Power Plants. The methodology has been applied to the 3rd and 13th Plant Operational States (POSs) as a Pilot experience. These POSs are within the operating mode 4 (Hot Shutdown) of a 3 loops Westinghouse Pressurized Water Reactor. The addressed Guide requires the operability of ju...
Citació
Martínez Cid, M., Dies, J., Tapia, C., Diaz, P. Outage Key Safety Functions Configuration risk assessment for a three loops Westinghouse PWR. "Nuclear engineering and design", 01 Setembre 2015, vol. 291, p. 271-276.
Paraules clau
Core Damage Frequency, Outage Key Safety Functions, Performance Technical Specifications., Plant Operational State, Probabilistic Safety Assessment
Grup de recerca
NERG - Grup de Recerca d´Enginyeria Nuclear

Participants

Arxius