Graphic summary
  • Show / hide key
  • Information


Scientific and technological production
  •  

1 to 45 of 45 results
  • Access to the full text
    Registration of X-rays at 2500 m altitude in association with lightning flashes and thunderstorms  Open access

     Montaña Puig, Juan; Fabro Tapia, Ferran; Van Der Velde, Oscar Arnoud; Romero Duran, David; Sola De Las Fuentes, Gloria; Hermoso Costa, Juan Ramon; Soula, Serge; Williams, Earle; Pineda Ruegg, Nicolau
    Journal of geophysical research: atmospheres
    Date of publication: 2014
    Journal article

    Read the abstract Read the abstract Access to the full text Access to the full text Open in new window  Share Reference managers Reference managers Open in new window

    Electric fields and high-energy radiation of natural lightning measured at close range from a mountaintop tower are discussed. In none of the 12 negative cloud-to-ground upward flashes were X-rays observed. Also no energetic radiation was found in one negative upward leader at close range (20¿m). In the first of two consecutive negative cloud-to-ground flashes, X-rays were detected during the last ~1.75¿ms of the leader. During the time of energetic radiation in the flash an intense burst of intracloud VHF sources was located by the interferometers. The X-ray production is attributed to the high electric field runaway electron mechanism during leader stepping. Even though the second flash struck closer than the previous one, no X-rays were detected. The absence of energetic radiation is attributed to being outside of the beam of X-ray photons from the leader tip or to the stepping process not allowing sufficiently intense electric fields ahead of the leader tip. High-speed video of downward negative leaders at the time when X-rays are commonly detected on the ground revealed the increase of speed and luminosity of the leader. Both phenomena allow higher electric fields at the leader front favoring energetic radiation. Background radiation was also measured during thunderstorms. The count rate of a particular day is presented and discussed. The increases in the radiation count rate are more coincident with radar reflectivity levels above ~30 dBZ than with the total lightning activity close to the site. The increases of dose are attributed to radon daughter-ion precipitation

    Electric fields and high-energy radiation of natural lightning measured at close range from a mountaintop tower are discussed. In none of the 12 negative cloud-to-ground upward flashes were X-rays observed. Also no energetic radiation was found in one negative upward leader at close range (20¿m). In the first of two consecutive negative cloud-to-ground flashes, X-rays were detected during the last ~1.75¿ms of the leader. During the time of energetic radiation in the flash an intense burst of intracloud VHF sources was located by the interferometers. The X-ray production is attributed to the high electric field runaway electron mechanism during leader stepping. Even though the second flash struck closer than the previous one, no X-rays were detected. The absence of energetic radiation is attributed to being outside of the beam of X-ray photons from the leader tip or to the stepping process not allowing sufficiently intense electric fields ahead of the leader tip. High-speed video of downward negative leaders at the time when X-rays are commonly detected on the ground revealed the increase of speed and luminosity of the leader. Both phenomena allow higher electric fields at the leader front favoring energetic radiation. Background radiation was also measured during thunderstorms. The count rate of a particular day is presented and discussed. The increases in the radiation count rate are more coincident with radar reflectivity levels above ~30 dBZ than with the total lightning activity close to the site. The increases of dose are attributed to radon daughter-ion precipitation

  • A propagative model for simulations of electric fields produced by downward leaders

     Hermoso Costa, Juan Ramon; Montaña Puig, Juan; March Nomen, Victor; Van Der Velde, Oscar Arnoud; Sola De Las Fuentes, Gloria; Romero Duran, David; Hermoso Alameda, Blas; Pineda Ruegg, Nicolau
    Journal of lightning research
    Date of publication: 2012-07-13
    Journal article

    View View Open in new window  Share Reference managers Reference managers Open in new window

  • Modelado y estudio del líder descendente negarivo en una descarga eléctrica atmosférica y su influencia en la localización del punto de impacto del rayo  Open access

     Hermoso Costa, Juan Ramon
    Defense's date: 2012-07-17
    Department of Electrical Engineering, Universitat Politècnica de Catalunya
    Theses

    Read the abstract Read the abstract Access to the full text Access to the full text Open in new window  Share Reference managers Reference managers Open in new window

    In lightning protection techniques a basic aspect is the identification of the impact point possible, which is determined by the evolution of the initial phase of the lightning, known as the stepped leader, the ground geometry and structures on it. In general, the available theoretical models are consistent with ideal situations and do not include situations such as non-vertical trajectories, non-flat terrain or complex structures. This work reviews and compares the most outstanding models in the literature on this subject and proposes a model for the study of the stepped leader based on the Finite Element Method (FEM). With the intention of bringing the process to the real situation of progress of a downward negative leader, who can follow a trajectory 3D, several modeling aspects are contemplated, as: adjusting the charge density in the channel, the length and direction of jump, which can be modified depending on the height that is the leader, and the propagation delays caused by the distance from the observation point. On the other hand, the model allows the implementation of 3D geometries and the incorporation of complex structures and non-flat terrain, providing results in situations when it is not possible to have theoretical approaches. Simulations have been performed with different proposals for charge distribution in the channel, in situations of leader vertical, inclined and 3D trajectory. The model has been evaluated, comparing their results with theoretical ideal cases and reproducing some real situations from field measurements. The application of the model in simulating real cases for downward negative leader provides parameter values that are not available through the recorded measurements and are useful for studying this type of discharge. In this work we have focused on some of them, and we have obtained interesting results as: estimating the speed of the leader according of height (from the measures of ¿E (t)), the definition of new relationships between charge density in the channel, ¿Emax (leader close to ground), the return peak current and the observation point distance, as well as we can verify the conditions of inception for a discharge into a storm cloud. Finally, we use the model to evaluate the striking distance, a basic concept on protection techniques. It is inferred a new equation for its calculus and the results are compared with proposals available in the literature, showing good agreement with the recommendation of IEC 62305-1. The results encourage to continue the study and they open the possibility to extend the method to other stages, not only on the downward leader, but also on other phenomena related to the formation and evolution of storm situations.

    En las técnicas de protección contra el rayo un aspecto básico es la identificación del posible punto de impacto, que viene determinado por la evolución de la fase inicial de la descarga atmosférica, conocida como líder escalonado (stepped leader), y por la geometría del terreno y estructuras sobre él. En general, los modelos teóricos disponibles se ajustan a situaciones ideales y no contemplan situaciones como trayectorias no verticales, terreno no plano o estructuras complejas. En este trabajo se revisan y comparan los modelos más destacados en la bibliografía sobre el tema y se propone un modelo para el estudio del stepped leader basado en el Método de los Elementos Finitos (FEM). Con la intención de aproximar el proceso a la situación real de avance de un líder negativo descendente, que puede seguir una trayectoria 3D, en el modelado se contemplan aspectos como: el ajuste de la densidad de carga en el canal, la longitud y dirección del salto, que pueden ser modificadas en función de la altura a la que se encuentre el líder, y los retardos de propagación provocados por la distancia del punto de observación. Por otra parte, el modelo permite la implementación de geometrías en 3D y la incorporación de estructuras complejas y terreno no plano, facilitando obtener resultados en situaciones en las que no es posible disponer de aproximaciones teóricas. Se han realizado simulaciones con diferentes propuestas de distribución de carga en el canal y para situaciones de líder vertical, inclinado y con trayectoria 3D. El modelo ha sido evaluado, contrastando sus resultados con casos teóricos ideales y reproduciendo situaciones reales a partir de diversas medidas de campo. La aplicación del modelo en la simulación de casos reales para líder negativo descendente nos proporciona valores de parámetros que no están disponibles a través de las medidas registradas y que son de utilidad para el estudio de las descargas negativas descendentes. En este trabajo nos hemos centrado en algunos de ellos y se han obtenido resultados de interés como: una estimación de la velocidad de avance del líder en función de la altura (a partir de medidas disponibles de ΔE(t)), la definición de nuevas relaciones entre densidad de carga en el canal, ΔEmax (líder próximo a tierra), la corriente de pico de retorno y la distancia del punto de observación, además de verificar las condiciones de inicio de descargas en una nube de tormenta. Por último, se utiliza el modelo para la evaluación de la distancia de cebado (striking distance), concepto básico en técnicas de protección. Se infiere una nueva ecuación para su cálculo y se comparan los resultados con las propuestas disponibles en la literatura, mostrando una buena concordancia con la recomendación de la norma IEC 62305-1. Los resultados obtenidos animan a continuar con el estudio y abren la posibilidad de ampliar la aplicación del método a otras etapas, no sólo en la descarga descendente, sino también de otros fenómenos relacionados con la formación y evolución de las situaciones de tormenta.

    En les tècniques de protecció contra el llamp, un aspecte bàsic és la identificació del possible punt d’impacte, que ve determinat per l’evolució de la fase inicial de la descàrrega atmosfèrica, coneguda com a líder esglaonat (stepped leader), i per la geometria del terreny i les estructures que hi ha a sobre d’ell. En general, els models teòrics dsiponibles s’ajusten a situacions ideals i no contemplen situacions com trajectòries no verticals, terreny no pla o estructures complexes. En aquest treball es revisen i comparen els models més destacats en la bibliografia sobre el tema i es proposa un model per a l’estudi del stepped leader basat en el Mètode dels Elements Finits (FEM). Amb la intenció d’apropar el procés a la situació real d’avançament d’un líder negatiu descendent, el qual pot seguir una trajetòria 3D, en el modelat es contemplemn aspectes com: l’ajustament de la densitat de càrrega al canal, la longitud i la direcció del salt, que poden ser modificades en funció a l’altura on es trobi el líder i als retards de propagació provocats per la distància del punt d’observació. D’una altra banda, el model permet la implementació de geometries en 3D i la incorporació d’estructures complexes i terreny no pla, facilitant així l’obtenció de resultats en situacions on no es possible disposar d’aproximacions teòriques. S’han realitzat simulacions amb diferents propostes de distribució de càrrega al canal i per a situacions de líder vertical, inclinat i amb trajectòria 3D. El model ha estat avaluat, contrastant els seus resultats amb casos teòrics ideals i reproduint situacions reals a partir de diferents mesures de camp. L’aplicació del model en la simulació de casos reals per a líder negatiu descendent ens proporciona valors de paràmetres que no estan disponibles a travès de les mesures registrades i que són d’utilitat per a l’estudi de les descàrregues negatives descendents. En aquest treball ens n’hem centrat en alguns i s’han obtingut resultats d’interès com: una estimació de la velocitat d’avançament del líder en funció d’altura (només a partir de mesures disponibles de ΔE(t)), la definició de les noves relacions entre densitat de càrrega al canal, ΔEmax (líder proper a terra), el corrent del pic de retorn i la distància del punt d’observació, a més de verificar les condicions d’inici de descàrregues en un núvol de tempesta. Per últim, s’utilitza el model per a l’avaluació de la distància de d'encebament (striking distance), concepte bàsic en tècniques de protecció. S’infereix una nova equació per al seu càlcul i es comparen els resultats amb les propostes disponibles en la literatura, mostrant una bona concordància amb la recomanació de la norma IEC 62305-1. Els resultats obtinguts animen a continuar amb l’estudi i obren la posibilitat d’ampliar l’aplicació del mètode a d’altres etapes, no només en la descàrrega descendent, sinó també d’altres fenòmens relacionats amb la formació i evolució de les situacions de tempesta.

  • TECCIT12-1-0009-10 - Pla de transferencia tecnologica pttu de la Univeristat Politècnica de Catalunya

     Rodriguez Cortes, Pedro; Luna Alloza, Alvaro; Hermoso Costa, Juan Ramon; Candela Garcia, Jose Ignacio; Rocabert Delgado, Joan; Muñoz Aguilar, Raul Santiago; Herrera Arias, Lidia
    Participation in a competitive project

     Share

  • A three-phase hybrid filter for medium voltage applications using an H-bridge

     Candela Garcia, Jose Ignacio; Rodriguez Cortes, Pedro; Nisak, Khairul; Rauma, Kalle; Hermoso Costa, Juan Ramon; Etxeberria, Ion
    European Conference on Power Electronics and Applications
    Presentation's date: 2011-08-30
    Presentation of work at congresses

    Read the abstract Read the abstract View View Open in new window  Share Reference managers Reference managers Open in new window

    This paper presents a new solution for filtering current harmonics in three-phase thee-wire medium voltage networks. The hybrid filter topology presented in this paper is characterized by the use of an HBridge instead of the usual thee-phase inverter. This H-bridge is directly connected in series with a passive filter tuned around sixth harmonic. This paper provides a theoretical explanation on voltage control of Hbridge in three-phase systems. The good performance of this new topology as well as the proposed controller will be evaluated by means of simulations.

  • Current control method for distributed generation power generation plants under grid fault conditions

     Rodriguez Cortes, Pedro; Luna Alloza, Alvaro; Hermoso Costa, Juan Ramon; Etxeberria Otadui, Ion; Teodorescu, Remus; Blaabjerg, Frede
    Annual Conference of the IEEE Industrial Electronics Society
    Presentation's date: 2011-11-07
    Presentation of work at congresses

    Read the abstract Read the abstract View View Open in new window  Share Reference managers Reference managers Open in new window

    The operation of distributed power generation systems under grid fault conditions is a key issue for the massive integration of renewable energy systems. Several studies have been conducted to improve the response of such distributed generation systems under voltage dips. In spite of being less severe, unbalanced fault cause a great number of disconnections, as it may produce the injection of unbalanced currents that can easily conduct to the tripping of the converter. In this paper a current control strategy for power converters able to deal with these grid conditions, without exceeding the current ratings of the converter is introduced. Moreover, a novel flexible algorithm has been proposed in order to regulate easily the injection of positive and negative currents for general purpose applications.

  • FILTRO INTELIGENTE DE POTENCIA PARA SISTEMAS EÓLICOS

     Candela Garcia, Jose Ignacio; Bogarra Rodriguez, Santiago; Rocabert Delgado, Joan; Luna Alloza, Alvaro; Hermoso Costa, Juan Ramon; Aldabas Rubira, Emiliano; Rodriguez Cortes, Pedro
    Participation in a competitive project

     Share

  • Access to the full text
    High-speed videos of laboratory leaders emerging from wind turbine blade tips  Open access

     Montaña Puig, Juan; March Nomen, Victor; Hermoso Alameda, Blas; Hermoso Costa, Juan Ramon
    International Conference on Lightning Protection
    Presentation's date: 2010-09-13
    Presentation of work at congresses

    Read the abstract Read the abstract Access to the full text Access to the full text Open in new window  Share Reference managers Reference managers Open in new window

    This paper presents some observation results of the attachment test of a wind turbine blade as described in the upgrade of the IEC-61400-24. The optical observations were performed by means of high-speed video and UV-sensitive photo camera. This study investigates the effects on the leaders emerging from the blade comparing three different air-terminals: discrete receptors, discrete receptors with diverter strips and metallic tip. In the first two types, salt mist pollution was applied to the blade. For non polluted tips positive leaders appeared from receptors towards the ground avoiding the blade surface. When the blade was polluted additional leaders emerged moving horizontally. Moreover, in this situation the leader progressed on the blade surface. Pollution also produced the inception of more leaders when the blade was equipped with discrete receptors and diverter strips.

  • A propagative model for simulations of electric fields produced by downward leaders

     Hermoso Costa, Juan Ramon; Montaña Puig, Juan; March Nomen, Victor; Romero Duran, David; Sola De Las Fuentes, Gloria; Van Der Velde, Oscar Arnoud
    International Conference on Lightning Protection
    Presentation's date: 2010-09-13
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • CONTROL DE SISTEMES ELECTRICS D'ENERGIA RENOVABLE

     Aldabas Rubira, Emiliano; Castilla Fernandez, Miguel; Guerrero Zapata, Josep Maria; Candela Garcia, Jose Ignacio; Rocabert Delgado, Joan; Vasquez Quintero, Juan Carlos; Hermoso Costa, Juan Ramon; Bogarra Rodriguez, Santiago; Jornet Alvarez, Atanasi; Rolan Blanco, Alejandro; Luna Alloza, Alvaro; Miret Tomas, Jaume; Rodriguez Cortes, Pedro; Font Mateu, Josep; Matas Alcala, Jose; Garcia de Vicuña Muñoz de la Nava, Jose Luis
    Participation in a competitive project

     Share

  • Advanced Wide Band Gap Semiconductor Devices for Rational Use of Energy (RUE)

     Candela Garcia, Jose Ignacio; Luna Alloza, Alvaro; Hermoso Costa, Juan Ramon; Rodriguez Cortes, Pedro
    Participation in a competitive project

     Share

  • Técnicas Avanzadas de Control de Sistemas Fotovoltaicos de Generacion Distribuida para Favorecer su Integracion en la Red Electrica (ENE2008-06841-C02-01/ALT, sub-proyecto de ENE2008-06841-C02-00/ALT))

     Hermoso Costa, Juan Ramon; Rodriguez Cortes, Pedro; Candela Garcia, Jose Ignacio; Aldabas Rubira, Emiliano; Jornet Alvarez, Atanasi
    Participation in a competitive project

     Share

  • TÉCNICAS AVANZADAS DE CONTROL DE SISTEMAS FOTOVOLTAICOS DE GENERACIÓN DISTRIBUIDA PARA FAVORECER SU INTEGRACIÓN EN LA RED ELECTRICA

     Hermoso Costa, Juan Ramon; Bogarra Rodriguez, Santiago; Jornet Alvarez, Atanasi; Aldabas Rubira, Emiliano; Candela Garcia, Jose Ignacio; Rodriguez Cortes, Pedro
    Participation in a competitive project

     Share

  • 2º SIMPOSIO SOBRE INTEGRACION EN LA RED ELECTRICA DE ENERGIA EOLICA

     Muñoz Aguilar, Raul Santiago; Rocabert Delgado, Joan; Luna Alloza, Alvaro; Aldabas Rubira, Emiliano; Hermoso Costa, Juan Ramon; Candela Garcia, Jose Ignacio; Rodriguez Cortes, Pedro
    Participation in a competitive project

     Share

  • Access to the full text
    Multiple second order generalized integrators for harmonic synchronization of power converters  Open access

     Rodriguez Cortes, Pedro; Luna Alloza, Alvaro; Etxebarría, Ion; Hermoso Costa, Juan Ramon; Teodorescu, Remus
    IEEE Energy Conversion Congress and Exposition
    Presentation's date: 2009-09-17
    Presentation of work at congresses

    Read the abstract Read the abstract Access to the full text Access to the full text Open in new window  Share Reference managers Reference managers Open in new window

    This paper presents a new frequency-adaptive synchronization method for grid-connected power converters which allows estimating not only the positive- and negativesequence components of the power signal at the fundamental frequency, but also other sequence components at multiple frequencies. The proposed system is called the MSOGI-FLL since it is based on a decoupled network consisting of multiple second order generalized integrators (MSOGI) which are frequency-adaptive by using a frequency-locked loop (FLL). In this paper, the MSOGI-FLL is analyzed and its performance is evaluated by both simulations and experiments.

  • Laser beam influence in the initiation and streamer propagation

     March Nomen, Victor; Montaña Puig, Juan; Arrayás, Manuel; Trueba, Jose Luis; Sola De Las Fuentes, Gloria; Romero Duran, David; Hermoso Costa, Juan Ramon
    International Conference on Lightning Protection
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Fast current impulse test for wind-turbine blades

     Montaña Puig, Juan; Clapers, Pere; Hermoso Alameda, Blas; March Nomen, Victor; Sola De Las Fuentes, Gloria; Illa Arnau, Àngel; Romero Duran, David; Aranguren Fino, Daniel; Hermoso Costa, Juan Ramon
    European Electromagnetics
    Presentation's date: 2008-07-21
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • First Steps on The "Eagle Nest" Instrumented Tower in Spain

     Montaña Puig, Juan; Romero Duran, David; Hermoso Costa, Juan Ramon; Sola De Las Fuentes, Gloria
    28th International Conference on Lightning Protection
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Procesado de la señal dentro del curriculum de Técnicos de las artes del espectáculo

     Martinez Barrios, Luis; Aldabas Rubira, Emiliano; Corbalán Fuertes, Montserrat; Hermoso Costa, Juan Ramon; Arias Pujol, Antoni; Rodriguez Cortes, Pedro; Ruiz, F.
    Congreso de Tecnologías Aplicadas a la Enseñanza de la Electrónica
    Presentation's date: 2006-07-13
    Presentation of work at congresses

    View View Open in new window  Share Reference managers Reference managers Open in new window

  • Resultado de las medidas de campo eléctrico y electrostático para la caracterización de rayos

     Montaña Puig, Juan; Hermoso Costa, Juan Ramon; Romero Duran, David; Hermoso Alameda, Blas
    Reunión de Grupos de Investigación de Ingeniería Eléctrica
    Presentation's date: 2004
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Modelo para el estudio de la demanda de energía eléctrica en el sector residencial

     Hermoso Costa, Juan Ramon
    XIII reunión de grupos de investigación de ingeniería eléctrica
    Presentation's date: 2003-04-09
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Modelo para el estudio de la demanda de energía eléctrica en el sector residencial

     Hermoso Costa, Juan Ramon; Pindado Rico, Rafael
    XIII reunión de grupos de investigación de ingeniería eléctrica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Análisis del contenido armónico de la demanda doméstica

     Hermoso Costa, Juan Ramon; Pindado Rico, Rafael
    XII Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Método de evaluación de riesgos en las puestas a tierra provisionales de líneas de alta tensión

     Candela Garcia, Jose Ignacio; Rodriguez Cortes, Pedro; Hermoso Costa, Juan Ramon
    XII Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Análisis del plan de estudios de Ingeniería Técnica Industrial en tres centros diferentes (UPNA- UJAEN- UPC)

     Hermoso Costa, Juan Ramon
    XII Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation's date: 2002-03-21
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Valoracion energética de la potencia reactiva en convertidores DC-AC con PWM

     Pindado Rico, Rafael; Hermoso Costa, Juan Ramon
    XII Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Laboratorio Virtual Dotado con Estación de Control de Procesos

     Hermoso Costa, Juan Ramon
    Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation's date: 2001-04-05
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Necesidad de la utilización de márketing en la oferta universitaria

     Pindado Rico, Rafael; Hermoso Costa, Juan Ramon
    Congreso Universitario de Innovación Educativa en las Enseñanzas Técnicas
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Una propuesta para la mejora de la calidad de vida del profesorado universitario basada en el reconocimiento de su trayectoria

     Pindado Rico, Rafael; Hermoso Costa, Juan Ramon; Gallardo Leon, Juan Antonio
    Congreso Universitario de Innovación Educativa en las Enseñanzas Técnicas
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Modelo continuo promediado de un acondicionador unificado de calidad de potencia para redes trifásica de cuatro hilos

     Rodriguez Cortes, Pedro; Candela Garcia, Jose Ignacio; Hermoso Costa, Juan Ramon
    Simposio Internacional sobre Calidad de Energía Eléctrica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Análisis de riesgos en las puestas a tierra provisionales para el mantenimiento de líneas de alta tensión

     Candela Garcia, Jose Ignacio; Rodriguez Cortes, Pedro; Hermoso Costa, Juan Ramon; Javier, Fco Casas
    Simposio Internacional sobre Calidad de Energía Eléctrica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Páginas web didácticas. Estudio de los recursos disponibles

     Hermoso Costa, Juan Ramon
    Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation's date: 2001-04-05
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Metodología de Síntesis de Convertidores Estáticos

     Hermoso Costa, Juan Ramon
    Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation's date: 2001-04-05
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Elementos de futuro en la enseñanza de la ingeniería técnica industrial en electricidad.

     Hermoso Costa, Juan Ramon
    Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation's date: 2001-04-05
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • El futuro de la Ingenieria Técnica Industrial Eléctrica

     Pindado Rico, Rafael; Hermoso Costa, Juan Ramon
    Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Average model of unfied power quality conditionerfor three-phase four-wire networks

     Rodriguez Cortes, Pedro; Candela Garcia, Jose Ignacio; Hermoso Costa, Juan Ramon
    International Sysmposium on Power Quality (SICEL'01)
    Presentation's date: 2001-11-01
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Elementos de futuro en la enseñanza de la ingeniería técnica industrial en electricidad

     Hermoso Costa, Juan Ramon; Pindado Rico, Rafael
    Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Normativa y factores de regulación de la calidad del servicio eléctrico en redes públicas de baja y media tensión

     Hermoso Costa, Juan Ramon
    X Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation's date: 2000-03-16
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Estructura y prestaciones de un sistema de información dedicado a la docencia semipresencial

     Hermoso Costa, Juan Ramon
    Congrés Internacional de Docència Universitària i Innovació
    Presentation's date: 2000-06-26
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Colaboración en el diseño y desarrollo de un sistema de cine digital

     Hermoso Costa, Juan Ramon; Marco Gomez, Jordi; Lopez Palma, Manuel
    Participation in a competitive project

     Share

  • Estructura y prestaciones de un sistema de información destinado a docencia semipresencial

     Rodriguez Cortes, Pedro; Pindado Rico, Rafael; Hermoso Costa, Juan Ramon
    Congrés Internacional de Docència Universitària i Innovació
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Normativa y factores de regulación de la calidad de servicio eléctrico en redes públicas de baja y media tensión

     Pindado Rico, Rafael; Hermoso Costa, Juan Ramon
    X Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Normativa y factores de regulación de la calidad del servicio eléctrico en redes públicos de baja y media tensión

     Hermoso Costa, Juan Ramon
    X Reunión de Grupos de Investigación en Ingeniería Eléctrica
    Presentation's date: 2000-03-16
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Planificación estratégica y evaluación un proceso continuo hacia la calidad

     Hermoso Costa, Juan Ramon
    PLANIFICACIÓN ESTRATÉGICA Y EVALUACIÓN. UN PROCESO CONTINUA HACIA LA CALIDAD.
    Presentation's date: 1999-09-15
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Planificacion estrategica y evaluacion: un proceso continuo hacia la calidad

     Pindado Rico, Rafael; Hermoso Costa, Juan Ramon; Ros Florenza, Joaquin
    Congreso Universitario de Innovación Educativa en las Enseñanzas Técnicas
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window