Graphic summary
  • Show / hide key
  • Information


Scientific and technological production
  •  

1 to 26 of 26 results
  • Spherical refractive correction with an electro-optical iquid lens in a double-pass system

     Sanàbria Ortega, Ferran; Díaz Doutón, Fernando; Aldaba Arevalo, Mikel; Pujol Ramo, Jaume
    Journal of the European Optical Society: rapid publications
    Date of publication: 2013-09-06
    Journal article

    Read the abstract Read the abstract View View Open in new window  Share Reference managers Reference managers Open in new window

    In this study we show a novel double-pass configuration to correct the spherical refractive error by means of an electro-optical liquid lens. The proposed method enables spherical correction in the -12 D to +7 D range without movable parts using an electro-optical liquid lens. We have measured the optical performance of the spherical corrector in terms of power, pupil size and optical quality verifying that it fits the requirements to be applied to a double-pass system. We have also evaluated the performance of the proposed method in patients by comparison with a conventional double-pass system using a Badal optometer.

  • Age-related changes in accommodation measured with a double-pass system

     Aldaba Arevalo, Mikel; Vilaseca Ricart, Meritxell; Arjona Carbonell, Maria Montserrat; Pujol Ramo, Jaume
    Ophthalmic and physiological optics
    Date of publication: 2013-07
    Journal article

    Read the abstract Read the abstract View View Open in new window  Share Reference managers Reference managers Open in new window

    To measure the accommodative response in a wide age range population using the retinal image quality assessments provided by a double-pass system.

  • Evaluation of an autorefractor for over-refraction with multifocal contact lenses patients

     Giner Tort, Anna; Aldaba Arevalo, Mikel; Arjona Carbonell, Maria Montserrat; Pujol Ramo, Jaume
    Association for Research in Vision and Ophthalmology Annual Meeting
    Presentation's date: 2013-05-09
    Presentation of work at congresses

    Read the abstract Read the abstract  Share Reference managers Reference managers Open in new window

    Non-cyclopegic distance refractive error was measured in patients wearing multifocal contact lenses by means of the Grand Seiko Auto Ref/Keratometer WAM-5500 auto-refractometer and compared with subjective measurements. Three commercial multifocal contact lenses were evaluated: Air Optix Multifocal, Ciba Vision (refractive bi-aspheric lens with near vision in the centre), Proclear Multifocal, CooperVision (refractive lens with aspheric centre with near vision in it), Acuvue Oasys Multifocal, Johnson & Johnson (refractive lens with a multicurve design). 30 eyes of 15 healthy adults were measured in the study. The results of over-refraction were evaluated in terms of M, J0 and J45. The mean difference between auto-refractometer and subjective spherical over-refraction was 0.52 ± 0.37D (range: +1.08 to +0.02D) for the Air Optix lens, 0.62 ± 0.43D (range: +0.94 to +0.32D) for the Proclear lens and -0.15 ± 0.11D (range: +0.07 to -0.46D) for the Acuvue Oasys lens. The mean differences in astigmatic over-refraction in terms of J0 and J45 were -0.04 ± 0.03D (range: +0.32 to -0.55) and -0.05 ± 0.04D (range: +0.15 to -0.31D) for the Air Optix lens, 0.17 ± 0.07D (range: +0.22 to +0.12D) and 0.05 ± 0.04D (range: +0.42 to -0.33D) for the Proclear lens and -0.23 ± 0.17D (range: +0.03 to -0.50D) and -0.05 ± 0.03D (range: +0.17 to -0.29D) for the Acuvue Oasys lens. We have measured the over-refraction in multifocal contact lenses users with an auto-refractometer and compared with subjective over-refraction. The results from our measurements highlighted a good agreement between subjective and objective values in both spherical and cylindrical refractions, although some discrepancies were found on patients with high refractive errors. Thus, we can conclude that auto-refractor is a useful tool for over-refraction in patients wearing multifocal contact lenses although care must be taken in highly myopic or hyperopic users.

  • Access to the full text
    Measuring the accommodative response with a double-pass system: comparison with the Hartmann-Shack technique  Open access

     Aldaba Arevalo, Mikel; Vilaseca Ricart, Meritxell; Diaz Douton, Fernando; Arjona Carbonell, Maria Montserrat; Pujol Ramo, Jaume
    Vision research
    Date of publication: 2012-04
    Journal article

    Access to the full text Access to the full text Open in new window  Share Reference managers Reference managers Open in new window

  • Access to the full text
    Optics of astigmatism and retinal image quality  Open access

     Vilaseca Ricart, Meritxell; Diaz Douton, Fernando; Luque, Sergio Oscar; Aldaba Arevalo, Mikel; Arjona Carbonell, Maria Montserrat; Pujol Ramo, Jaume
    Date of publication: 2012-02
    Book chapter

    Read the abstract Read the abstract Access to the full text Access to the full text Open in new window  Share Reference managers Reference managers Open in new window

    In the first part of this chapter, the optical condition of astigmatism is defined. The main causes and available classifications of ocular astigmatism are briefly described. The most relevant optical properties of image formation in an astigmatic eye are analysed and compared to that of an emmetropic eye and an eye with spherical ametropia. The spectacle prescription and axis notation for astigmatism are introduced, and the correction of astigmatism by means of lenses is briefly described. The formation of the retinal image for extended objects and the related blurring are also analysed, and the real limits of tolerance of uncorrected astigmatism are provided. Simulations of retinal images in astigmatic eyes, obtained by means of commercial optical design software, are also presented. Finally, the clinical assessment of retinal image quality by means of wavefront aberrometry and double-pass systems in eyes with astigmatism is presented, and current trends in research related to this topic are highlighted.

  • Medida de la respuesta acomodativa con un sistema de doble paso. Aplicación al estudio de la acomodación en función de la edad.  Open access

     Aldaba Arevalo, Mikel
    Defense's date: 2012-10-22
    Department of Optics and Optometry, Universitat Politècnica de Catalunya
    Theses

    Read the abstract Read the abstract Access to the full text Access to the full text Open in new window  Share Reference managers Reference managers Open in new window

    Accommodation, defined as the dioptric change of the eye, enables clear vision at different distances. Its study is interesting due to different aspects: the progressive loss of amplitude of accommodation known as presbyopia, the recent interest in accommodative restauration techniques in pseudophakic patients, its possible relation to myopia development and the associated pathologies. The most widely used techniques to measure accommodation are the subjectives, although it has been shown that they overestimate accommodation due to pseudoaccommodation. There are also several objective techniques as retinoscopy, autorefractometers or aberrometers. In the last years it has been suggested that a more realistic accommodative measurement is done when all the aberrations of the eye are taken into acount, and not just defocus. The goal of this thesis has been to develop a method based on the double pass technique for the accommodative response measurement and its application to the study of accommodation with age. Double pass technique is based on projecting a point source on the retina and recording images after retinal reflection and double pass through the ocular media. This technique provides information about the optical quality of the eye and takes into acount all the factors influencing the retinal image quality, thus it is ideal for being applied in the measurement of tha accommodative response. In the first part of the thesis the method for the accommodative response measurement based on double pass technique has been developed and it has been validated by comparison with Hartmann-Shack measurements. The developed experimental setup combines both techniques, double pass and Hartmann-Shack, and it is specifically designed for accommodative response measurements, including elements like the open field fixation test that allows a more natural accommodative stimulation. The method developed is based on finding the vergence that maximizes the quality of the double pass image. Several double pass images are recorded by means of an axial scanning and the vergence of the best double pass image is related to accommodative response. Double pass measurements showed a good agreement with Hartmann-Shack measurements and no statistically significant differences, thus validating our method. In the second part of the thesis, the method has been applied for the study of the accommoditve response in a wide age range population. The accommodative response measured in young patients was higher than the published in the literature, due to our measurements being based on the retinal image quality and not on defocus. While in older patients, the accommodative response measurements are in good agreement with previous works. The accommodative stimulus-response curve and its slope also showed a worsening with age, with a more noticeable change in the accommodation after the age of 35-40 years. The work done during the thesis led to articles in journals and several contributions to congresses, as well as to a patent being comercially exploited.

    La acomodación, cambio dióptrico del ojo, permite una visión nítida a diferentes distancias. El interés que despierta su estudio es grande debido a diferentes factores: la progresiva pérdida de acomodación con la edad, la restauración de la acomodación en pacientes pseudfáquicos, su posible relación con el desarrollo de la miopía y las patologías asociadas a la acomodación. Aunque las técnicas más habituales para la medida de la acomodación son las técnicas subjetivas, presentan el problema de sobrevalorar la amplitud de acomodación debido a la pseudoacomodación, rango en el que sin cambio dióptrico del cristalino se ve nítidamente gracias a la profundidad de foco. Entre las objetivas se han propuesto diversas técnicas como la retinoscopía, autorrefractómetros o aberrómetros. En los últimos años se ha sugerido que una correcta medida de la acomodación no sólo debería tener en cuenta el desenfoque si no el global de las aberraciones que afectan a la calidad de la imagen retiniana. El objetivo de esta tesis ha sido desarrollar un nuevo método para la medida de la respuesta acomodativa basado en la técnica de doble paso y su aplicación al estudio de la acomodación con la edad. La técnica de doble paso consiste en proyectar una fuente puntual de luz en la retina y registrar la imagen formada tras su reflexión en la retina y doble paso por los medios oculares. Esta técnica da información acerca de la calidad óptica del ojo y tiene en cuenta los dos factores que afectan básicamente a la calidad de la imagen retiniana: aberraciones y difusión intraocular, lo que la convierte en una candidata ideal para su aplicación en la medida de la respuesta acomodativa. En la primera parte de la tesis se ha desarrollado un método y un montaje para la medida de la respuesta acomodativa con un sistema de doble paso y se ha validado mediante comparación con medidas realizadas con un aberrómetro de Hartmann-Shack. El montaje experimental desarrollado combina ambas técnicas, doble paso y Hartmann-Shack, y además está optimizado para la medida de la respuesta acomodativa con un test de fijación de campo abierto que permite una estimulación de la acomodación más natural que los test internos. El método desarrollado se basa en hallar la vergencia de la luz que maximiza la calidad de la imagen de doble paso. Para ello se registran diversas imágenes de doble paso correspondientes a diferentes vergencias de la luz y la de mayor calidad se relaciona con la respuesta acomodativa. Las medidas realizadas con el sistema de doble paso se han comparado con medidas simultáneas realizadas con un aberrómetro de Hartmann-Shack, obteniendo resultados similares con ambas técnicas. Una vez validado el método para la medida de la respuesta acomodativa con el sistema de doble paso, se ha aplicado al estudio de los cambios en la acomodación con la edad realizando medidas en una población extensa con un rango amplio de edad. La respuesta acomodativa medida en los pacientes jóvenes es mayor que en otros trabajos, básicamente debido a que la técnica empleada está basada en la calidad de la imagen retiniana y no en el desenfoque como sucede en los otros estudios. Mientras que en pacientes mayores, los resultados concuerdan con los de otros estudios. La curva de estímulo-respuesta acomodativa y su pendiente muestran un empeoramiento con la edad, observándose que la edad que marca los cambios más notables está en torno a los 35-40 años. El trabajo realizado durante el desarrollo de la tesis ha dado lugar a publicaciones en revistas y diversas contribuciones a congresos, así como una patente actualmente explotada comercialmente.

  • Medida de la respuesta acomodativa con un sistema de doble paso

     Aldaba Arevalo, Mikel; Vilaseca Ricart, Meritxell; Diaz Douton, Fernando; Arjona Carbonell, Maria Montserrat; Pujol Ramo, Jaume
    Reunión Nacional de Óptica
    Presentation's date: 2012-09-06
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Measuring accommodative response with a double-pass system

     Aldaba Arevalo, Mikel; Vilaseca Ricart, Meritxell; Diaz Douton, Fernando; Arjona Carbonell, Maria Montserrat; Pujol Ramo, Jaume
    European Meeting on Visual and Physiological Optics
    Presentation's date: 2012-08-22
    Presentation of work at congresses

    View View Open in new window  Share Reference managers Reference managers Open in new window

  • Trabajos de investigación en óptica visual y tecnología del color en el CD6

     Pujol Ramo, Jaume; Arjona Carbonell, Maria Montserrat; Vilaseca Ricart, Meritxell; Aldaba Arevalo, Mikel; Diaz Douton, Fernando; Luque, Sergio Oscar; Zuluaga Duque, Harold; Herrera Ramirez, Jorge Alexis; Sanabrial, F.; Ferrer Serrano, Edgar; Martinez Roda, Juan Antonio; Ondategui Parra, Juan Carlos; Burgos, Francisco Javier; Giner Tort, Anna; Torrecilla Ribalta, Elena
    Reunión Nacional de Óptica
    Presentation's date: 2012-09-05
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Double-pass accommodative response measurements in a wide age range population

     Pujol Ramo, Jaume; Aldaba Arevalo, Mikel; Vilaseca Ricart, Meritxell; Diaz Douton, Fernando; Arjona Carbonell, Maria Montserrat
    Association for Research in Vision and Ophthalmology Annual Meeting
    Presentation's date: 2012-05
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • NUEVOS DESARROLLOS EN ÓPTICA VISUAL Y TECNOLOGÍA DEL COLOR CON ALTO IMPACTO SOCIAL E INDUSTRIAL

     Pujol Ramo, Jaume; Vilaseca Ricart, Meritxell; Arjona Carbonell, Maria Montserrat; Martinez Roda, Juan Antonio; Ondategui Parra, Juan Carlos; Aldaba Arevalo, Mikel; Zuluaga Duque, Harold; Herrera Ramirez, Jorge Alexis; Ferrer Serrano, Edgar
    Participation in a competitive project

     Share

  • Accommodative response measurements based on double pass images

     Aldaba Arevalo, Mikel; Vilaseca Ricart, Meritxell; Arjona Carbonell, Maria Montserrat; Pujol Ramo, Jaume
    Association for Research in Vision and Ophthalmology Annual Meeting
    Presentation's date: 2011-05
    Presentation of work at congresses

    View View Open in new window  Share Reference managers Reference managers Open in new window

  • Assessment of the optical quality with a double-pass system in eyes with contact lens induced corneal swelling

     Juan, Victoria de; Aldaba Arevalo, Mikel; Martín, Raúl; Vilaseca Ricart, Meritxell; Herreras, J. M.; Pujol Ramo, Jaume
    Association for Research in Vision and Ophthalmology Annual Meeting
    Presentation's date: 2011-05
    Presentation of work at congresses

    View View Open in new window  Share Reference managers Reference managers Open in new window

  • Defocus curve of multifocal intraocular lenses measured with a new asymmetric focus double pass system

     Zuluaga Duque, Harold; Diaz Douton, Fernando; Luque, Sergio Oscar; Aldaba Arevalo, Mikel; Arjona Carbonell, Maria Montserrat; Pujol Ramo, Jaume
    Association for Research in Vision and Ophthalmology Annual Meeting
    Presentation's date: 2010-05-06
    Presentation of work at congresses

    View View Open in new window  Share Reference managers Reference managers Open in new window

  • Comparison of accommodative response measurements with double pass and Hartmann Shack techniques

     Aldaba Arevalo, Mikel; Arjona Carbonell, Maria Montserrat; Vilaseca Ricart, Meritxell; Antò Roca, Joan; Pujol Ramo, Jaume
    European Meeting on Visual and Physiological Optics
    Presentation's date: 2010-08
    Presentation of work at congresses

    View View Open in new window  Share Reference managers Reference managers Open in new window

  • NUEVOS METODOS E INSTRUMENTACION PARA EL ESTUDIO DE LA OPTICA DEL OJO HUMANO E IMAGENES MULTIESCTRALES

     de Lasarte Rigueiro, Marta; Aldaba Arevalo, Mikel; Pladellorens Mallofre, Josep; Arjona Carbonell, Maria Montserrat; Vilaseca Ricart, Meritxell; Luque, Sergio Oscar; Martinez Roda, Juan Antonio; Ondategui Parra, Juan Carlos; Pujol Ramo, Jaume
    Participation in a competitive project

     Share

  • Líneas de Investigación en Óptica Visual y Tecnología del Color en el CD6

     Pujol Ramo, Jaume; Vilaseca Ricart, Meritxell; Arjona Carbonell, Maria Montserrat; Aldaba Arevalo, Mikel; Herrera Ramirez, Jorge Alexis; Ondategui Parra, Juan Carlos; de Lasarte, Marta; Zuluaga Duque, Harold; Diaz Douton, Fernando; Luque, Sergio Oscar; Sanàbria Ortega, Ferran
    Reunión Nacional de Óptica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Medida del retraso acomodativo con la técnica de doble paso

     Aldaba Arevalo, Mikel; Arjona Carbonell, Maria Montserrat; Diaz Douton, Fernando; Luque, Sergio Oscar; Pujol Ramo, Jaume
    Reunión Nacional de Óptica
    Presentation's date: 2009
    Presentation of work at congresses

    Read the abstract Read the abstract View View Open in new window  Share Reference managers Reference managers Open in new window

    La acomodación se define como el cambio dióptrico en la potencia del ojo, que permite ver nítidamente a diferentes distancias. La profundidad de foco del ojo hace que se puedan ver objetos cercanos nítidamente con menor esfuerzo acomodativo del requerido por su proximidad. A esta diferencia entre el plano de enfoque del ojo y el plano del objeto cercano se le llama retraso acomodativo, y en los último años su estudio ha sido de gran interés, principalmente, debido a la relación que pueda tener con el progreso de la miopía. Clásicamente, el retraso acomodativo se ha medido mediante retinoscopía dinámica, pero esta técnica depende del criterio del observador; es por ello que en los últimos tiempos se han realizado medidas utilizando autorrefratómetros o aberrómetros, donde se prescinde del criterio del observador. En el presente trabajo se ha medido el retraso acomodativo utilizando un sistema objetivo basado en la técnica de doble paso. La técnica de doble paso permite medir la calidad óptica del ojo y consiste en formar la imagen de un punto en la retina y registrar la imagen de la luz reflejada en la retina tras su doble paso por los medios oculares [1]. De su aplicación en el estudio del ojo acomodado [2] se sabe que la calidad la imagen retiniana no difiere sustancialmente del ojo acomodado. La idea de nuestro trabajo ha sido la de hallar la mejor imagen retiniana para diferentes estados acomodativos a fin de calcular el retraso acomodativo, y comparar los resultados con otras técnicas.

  • Objective Measurement of Amplitude of Accommodation Using a Double Pass Based System

     Pujol Ramo, Jaume; Aldaba Arevalo, Mikel
    Association for Research in Vision and Ophthalmology Annual Meeting
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Medida de la agudeza visual

     Marín, R; Aldaba Arevalo, Mikel; M, Sanz E
    Ver y oir
    Date of publication: 2007-10
    Journal article

     Share Reference managers Reference managers Open in new window

  • OQAS (Optical Quality Análisis System): un nuevo sistema para la evaluación clínica objetiva de la luz difusa, la acomodación y la calidad visual

     Pujol Ramo, Jaume; Diaz Douton, Fernando; Aldaba Arevalo, Mikel; Arjona Carbonell, Maria Montserrat; Luque, Sergio Oscar; Lapuente, V; Sanabria, F; Artal, P; Benito, A; Alcon, E
    Date of publication: 2007-01
    Book chapter

     Share Reference managers Reference managers Open in new window

  • Intraocular scattering estimation from double-pass MTFs

     Aldaba Arevalo, Mikel; Pujol Ramo, Jaume; Arjona Carbonell, Maria Montserrat; Diaz Douton, Fernando
    Association for Research in Vision and Ophthalmology Annual Meeting
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Medida y evaluación de la calidad óptica del ojo

     Aldaba Arevalo, Mikel; Pujol Ramo, Jaume; Diaz Douton, Fernando; Arjona Carbonell, Maria Montserrat
    Ver y oir
    Date of publication: 2007-01
    Journal article

     Share Reference managers Reference managers Open in new window

  • Medida de la birrefringencia óptica en las fibras textiles. Parte 1: Demostración teórica  Open access

     Aldaba Arevalo, Mikel; Antò Roca, Joan; Cayuela Marin, Diana; Morales López, Cristina
    Boletín Intexter del Instituto de Investigación Textil y de Cooperación Industrial
    Date of publication: 2006-12
    Journal article

    Read the abstract Read the abstract Access to the full text Access to the full text Open in new window  Share Reference managers Reference managers Open in new window

    En este trabajo se desarrollan los aspectos teóricos de la medida de la birrefringencia en cuerpos anisotrópicos por el método de Nikitin-Berek. También se desarrolla su aplicación específica a medidas de la birrefringencia en las fibras textiles en un microscopio de polarización con la ayuda de un compensador Berek. La importancia de la puesta a punto de esta técnica está relacionada con la medida indirecta de la orientación de las fibras a partir de valores de birrefringencia de manera que, cuanto mayor es la birrefringencia, mayor es la orientación de las macromoléculas en la dirección del eje de la fibra. This work sets out to examine the theoretical aspects of measuring birefringence in anisotropic bodies using the Nikitin-Berek method. This method is also used to develop a specific application for measuring birefringence in textile fibres under a polarizing microscope with the help of a Berek compensator. The importance of fine-tuning this technique is related to the indirect measurement of fibre direction based on birefringence values in such a way that the higher the birefringence, the higher the orientation of the macromolecules in the direction of the fibre¿s axis. Les travaux ont consisté à développer les aspects théoriques de la mesure de la biréfringence pour des corps anisotropiques selon la méthode de Nikitin-Berek. L¿application spécifique aux mesures de la biréfringence des fibres textiles est également développée avec un microscope polarisant équipé d¿un compensateur Berek. L¿importance de la mise au point de cette technique est liée à la mesure indirecte de l¿orientation des fibres à partir de valeurs de biréfringence de sorte que plus la biréfringence est importante, plus l¿orientation des macromolécules dans l¿axe de la fibre l¿est aussi

    En este trabajo se desarrollan los aspectos teóricos de la medida de la birrefringencia en cuerpos anisotrópicos por el método de Nikitin-Berek. También se desarrolla su aplicación específica a medidas de la birrefringencia en las fibras textiles en un microscopio de polarización con la ayuda de un compensador Berek. La importancia de la puesta a punto de esta técnica está relacionada con la medida indirecta de la orientación de las fibras a partir de valores de birrefringencia de manera que, cuanto mayor es la birrefringencia, mayor es la orientación de las macromoléculas en la dirección del eje de la fibra.

    This work sets out to examine the theoretical aspects of measuring birefringence in anisotropic bodies using the Nikitin-Berek method. This method is also used to develop a specific application for measuring birefringence in textile fibres under a polarizing microscope with the help of a Berek compensator. The importance of fine-tuning this technique is related to the indirect measurement of fibre direction based on birefringence values in such a way that the higher the birefringence, the higher the orientation of the macromolecules in the direction of the fibre’s axis.

    Les travaux ont consisté à développer les aspects théoriques de la mesure de la biréfringence pour des corps anisotropiques selon la méthode de Nikitin-Berek. L’application spécifique aux mesures de la biréfringence des fibres textiles est également développée avec un microscope polarisant équipé d’un compensateur Berek. L’importance de la mise au point de cette technique est liée à la mesure indirecte de l’orientation des fibres à partir de valeurs de biréfringence de sorte que plus la biréfringence est importante, plus l’orientation des macromolécules dans l’axe de la fibre l’est aussi.

  • Investigación en Óptica Fisiológica y Color en el Centro de Desarrollo de Sensores, Instrumentación y Sistemas

     Pujol Ramo, Jaume; de Lasarte Rigueiro, Marta; Vilaseca Ricart, Meritxell; Arjona Carbonell, Maria Montserrat; Aldaba Arevalo, Mikel; Diaz Douton, Fernando
    Reunión Nacional de Óptica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window

  • Medida de la amplitud de acomodación a partir del análisis de la calidad de la imagen retiniana

     Aldaba Arevalo, Mikel; Luque, Sergio Oscar; Diaz Douton, Fernando; Pujol Ramo, Jaume; Arjona Carbonell, Maria Montserrat
    Reunión Nacional de Óptica
    Presentation of work at congresses

     Share Reference managers Reference managers Open in new window