Resum
BRIKEN is a complex detection system to be installed at the RIB-facility of the RIKEN Nishina Center. It is aimed at the detection of heavy-ion implants, ß-particles, ¿-rays and ß-delayed neu- trons. The whole detection setup involves the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and a large set of 166 counters of 3He embedded in a high-density polyethy- lene matrix. This article reports on a novel methodology developed for the conceptual design and optimisation ...