Failure investigation of a Pelton turbine runner

Autor
Egusquiza, M.; Egusquiza, E.; Valentin, D.; Valero, M.; Presas, A.
Tipus d'activitat
Article en revista
Revista
Engineering failure analysis
Data de publicació
2017-11
Volum
81
Pàgina inicial
234
Pàgina final
244
DOI
https://doi.org/10.1016/j.engfailanal.2017.06.048 Obrir en finestra nova
Repositori
http://hdl.handle.net/2117/109565 Obrir en finestra nova
URL
http://www.sciencedirect.com/science/article/pii/S135063071630783X?via%3Dihub Obrir en finestra nova
Resum
In this paper, an uncommon failure of a Pelton turbine has been analyzed. After the monitoring system detected a sudden increase in the vibration levels, the turbine was inspected. The inspection showed that a fragment of one bucket broke off during operation. Moreover there were several buckets with cracks, always located in the same side of the buckets. An analysis of the detached fragment revealed a fatigue problem.After the damage was found, the vibration signatures measured by the monitorin...
Citació
Egusquiza, M., Egusquiza, E., Valentin, D., Valero, M., Presas, A. Failure investigation of a Pelton turbine runner. "Engineering failure analysis", Novembre 2017, vol. 81, p. 234-244.
Grup de recerca
CDIF - Centre de Diagnòstic Industrial i Fluidodinàmica
FLUIDS - Enginyeria de Fluids

Participants