Carregant...
Carregant...

Vés al contingut (premeu Retorn)

Resonance-based procedure for locating failed luminaires in AGL systems

Autor
Vidal, D.; Monjo, L.; Sainz, L.
Tipus d'activitat
Article en revista
Revista
IEEE transactions on aerospace and electronic systems
Data de publicació
2018-02
Volum
54
Número
1
Pàgina inicial
106
Pàgina final
114
DOI
https://doi.org/10.1109/TAES.2017.2735678 Obrir en finestra nova
Repositori
http://hdl.handle.net/2117/114109 Obrir en finestra nova
URL
http://ieeexplore.ieee.org/document/8000638/ Obrir en finestra nova
Resum
IEEE Aeronautical ground lighting (AGL) systems provide a visual reference for aircraft during airport operations. Fast detection and location of failed luminaires is an important safety concern in AGL systems. In the event of luminaire failure, AGL transformers introduce harmonic currents. Resonances can increase harmonics, worsening the problem. This paper presents analytical expressions for determining resonance frequencies in AGL systems, as well as a simple procedure based on these expressi...
Citació
Vidal, D., Monjo, L., Sainz, L. Resonance-based procedure for locating failed luminaires in AGL systems. "IEEE transactions on aerospace and electronic systems", Febrer 2018, vol. 54, núm. 1, p. 106-114.
Paraules clau
AGL systems, Circuit faults, Equivalent circuits, Harmonic analysis, Impedance, Power quality, Power transformers, Resonant frequency, failed luminaire location, harmonics, power quality, resonance
Grup de recerca
QSE - Qualitat del Subministrament Elèctric

Participants

Arxius