Comparison of four methods to simulate swelling in poroelastic finite element models of intervertebral discs

Autor
Galbusera, F.; Schmidt, H.; Malandrino, A.; Damien, D.; Wilke, H.; Shirazi-Adl, A.; Noailly, J.
Tipus d'activitat
Article en revista
Revista
Journal of the mechanical behavior of biomedical materials
Data de publicació
2011-10
Volum
4
Número
7
Pàgina inicial
1234
Pàgina final
1241
DOI
https://doi.org/10.1016/j.jmbbm.2011.04.008 Obrir en finestra nova
Repositori
http://hdl.handle.net/2117/13334 Obrir en finestra nova
Resum
Osmotic phenomena influence the intervertebral disc biomechanics. Their simulation is challenging and can be undertaken at different levels of complexity. Four distinct approaches to simulate the osmotic behaviour of the intervertebral disc (a fixed boundary pore pressure model, a fixed osmotic pressure gradient model in the whole disc or only in the nucleus pulposus, and a swelling model with strain-dependent osmotic pressure) were analysed. Predictions were compared using a 3D poroelastic fin...
Citació
Galbusera, F. [et al.]. Comparison of four methods to simulate swelling in poroelastic finite element models of intervertebral discs. "Journal of the mechanical behavior of biomedical materials", Octubre 2011, vol. 4, núm. 7, p. 1234-1241.
Grup de recerca
BIOMEC - Biomechanical Engineering Lab

Participants

  • Galbusera, Fabio  (autor)
  • Schmidt, Hendrik  (autor)
  • Malandrino, Andrea  (autor)
  • Lacroix, Damien  (autor)
  • Wilke, Hans-Joachim  (autor)
  • Shirazi-Adl, Aboulfazi  (autor)
  • Noailly, Jerome  (autor)