Carregant...
Carregant...

Vés al contingut (premeu Retorn)

Detection of demagnetization faults in surface-mounted permanent magnet synchronous motors by means of the zero-sequence voltage component

Autor
Urresty, J.; Riba, J.; Delgado Prieto, M.; Romeral, L.
Tipus d'activitat
Article en revista
Revista
IEEE transactions on energy conversion
Data de publicació
2012-03-01
Volum
27
Número
1
Pàgina inicial
42
Pàgina final
51
DOI
https://doi.org/10.1109/TEC.2011.2176127 Obrir en finestra nova
Repositori
http://hdl.handle.net/2117/16262 Obrir en finestra nova
URL
http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=6104129 Obrir en finestra nova
Resum
This paper develops and analyzes an online methodology to detect demagnetization faults in surface-mounted permanent magnet synchronous motors. The proposed methodology, which takes into account the effect of the inverter that feeds the machine, is based on monitoring the zero-sequence voltage component of the stator phase voltages. The theoretical basis of the proposed method has been established. Attributes of the method presented here include simplicity, very low computational burden, and hig...
Citació
Urresty, J. [et al.]. Detection of demagnetization faults in surface-mounted permanent magnet synchronous motors by means of the zero-sequence voltage component. "IEEE transactions on energy conversion", 01 Març 2012, vol. 27, núm. 1, p. 42-51.
Grup de recerca
MCIA - Motion Control and Industrial Applications Research Group
PERC-UPC - Centre de Recerca d'Electrònica de Potència UPC

Participants