Carregant...
Carregant...

Vés al contingut (premeu Retorn)

Comparative study of the performance of three cross-flow ceramic membranes for water treatment

Autor
Cremades, L.V.; Rodríguez-Grau, E.; Rafael, M.; Cusido, J.
Tipus d'activitat
Article en revista
Revista
Water SA
Data de publicació
2007-04
Volum
33
Número
2
Pàgina inicial
253
Pàgina final
259
DOI
https://doi.org/10.4314/wsa.v33i2.49083 Obrir en finestra nova
Repositori
http://hdl.handle.net/2117/19195 Obrir en finestra nova
URL
http://www.ajol.info/index.php/wsa/article/view/49083/35428 Obrir en finestra nova
Resum
Several tests using water as effluent are used to analyse the performance of three types of microfiltration cross-flow ceramic membranes. Two of these membranes are commercial (Atech and Membralox/US Filter) and the third one is experimental. The main differences between them lie in their chemical composition (different origin of raw materials) and in their manufacturing process. The results presented here show the dominant effect of the filtering and the gel layer. Both are formed during operat...
Citació
Cremades, L.V. [et al.]. Comparative study of the performance of three cross-flow ceramic membranes for water treatment. "Water SA", Abril 2007, vol. 33, núm. 2, p. 253-259.
Paraules clau
Ceramic membrane, Cross-flow, Filtration, Permeability
Grup de recerca
GIIP - Grup de Recerca en Enginyeria de Projectes: Disseny, Sostenibilitat i Comunicació

Participants

Arxius