Carregant...
Carregant...

Vés al contingut (premeu Retorn)

Validation of numerical flow simulations against in vitro phantom measurements in different type B aortic dissection scenarios

Autor
Soudah, E.; Rudenick, P.; Bordoné, M.; Bijnens, B.; Garcia-Dorado, D.; Evangelista, A.; Oñate, E.
Tipus d'activitat
Article en revista
Revista
Computer methods in biomechanics and biomedical engineering
Data de publicació
2015-06-11
Volum
18
Número
8
Pàgina inicial
805
Pàgina final
815
DOI
https://doi.org/10.1080/10255842.2013.847095 Obrir en finestra nova
Repositori
http://hdl.handle.net/2117/86517 Obrir en finestra nova
Resum
An aortic dissection (AD) is a serious condition defined by the splitting of the arterial wall, thus generating a secondary lumen [the false lumen (FL)]. Its management, treatment and follow-up are clinical challenges due to the progressive aortic dilatation and potentially severe complications during follow-up. It is well known that the direction and rate of dilatation of the artery wall depend on haemodynamic parameters such as the local velocity profiles, intra-luminal pressures and resultant...
Citació
Soudah, E., Rudenick, P., Bordoné, M., Bijnens, B., Garcia-Dorado, D., Evangelista, A., Oñate, E. Validation of numerical flow simulations against in vitro phantom measurements in different type B aortic dissection scenarios. "Computer Methods in Biomechanics and Biomedical Engineering", 11 Juny 2015, vol. 18, núm. 8, p. 805-815.
Paraules clau
COMPUTATIONAL FLUID-DYNAMICS, STRATEGIES, TEAR SIZE, aortic diseases, aortic dissection, computational fluid dynamics, in vitro phantoms