Determination of hexavalent chromium in leather by ion-exchange chromatography

Author
Font Vallès, Joaquim; Perez, C.; Reyes, M.; Cobos, M.; Combalia, F.; Marsal , A.
Type of activity
Journal article
Journal
Journal of the Society of Leather Technologists and Chemists
Date of publication
2014-09-01
Volume
98
Number
4
First page
151
Last page
157
Repository
http://hdl.handle.net/2117/26102 Open in new window
Abstract
The determination of traces of hexavalent chromium in leather and in leather consumer goods is carried out by ion-exchange chromatography. Samples are extracted at pH7.5-8 with a phosphate buffer, according to the method of the current ISO 17075 Standard. The extracts are filtered and analysed by HPLC using an ion-exchange stationary phase and a PDA detector, without any clean up process. An ammonium sulphate electrolyte at pH8 is used as mobile phase. The determination of the recovery yields ra...
Citation
Font Vallès, Joaquim [et al.]. Determination of hexavalent chromium in leather by ion-exchange chromatography. "Journal of the Society of Leather Technologists and Chemists", 01 Setembre 2014, vol. 98, núm. 4, p. 151-157.
Keywords
HPLC, Hexavalent Chromium, ion-exchange chromatography, leather