Intraocular scattering and the MTF peak correction applied to double-pass retinal images

Author
Garcia, C.E.; Martinez-Roda, J.A.; Aldaba, M.; Pujol, J.
Type of activity
Presentation of work at congresses
Name of edition
8th European Meeting on Visual and Physiological Optics
Date of publication
2016
Presentation's date
2016-08-23
Book of congress proceedings
VPO 2016: 8th European Meeting on Visual and Physiological Optics: book of abstracts
First page
172
Last page
174
Abstract
When the MTF is computed from double-pass (DP) retinal images, the modulation transfer function (MTF) presents typically a peak at zero frequency provoked by the constant background illumination that affects the point spread function (PSF) of the eye. Under conventional DP data processing, this peak is avoided by extrapolating the zero frequency from a curve fitting. In this work, we use the information removed by the peak correction process to estimate intraocular scattering by introducing an i...
Keywords
MTF peak correction, double-pass images, intraocular scattering