Pumps condition assessment in water distribution networks

Author
Soldevila, A.; Blesa, J.; Rosa M. Fernandez-Canti; Tornil-Sin, S.; Meseguer, J.; Puig, V.
Type of activity
Journal article
Journal
IFAC-PapersOnLine
Date of publication
2018-01-01
Volume
51
Number
24
First page
662
Last page
667
DOI
https://doi.org/10.1016/j.ifacol.2018.09.646 Open in new window
Repository
http://hdl.handle.net/2117/125818 Open in new window
URL
https://www.sciencedirect.com/science/article/pii/S2405896318323589 Open in new window
Abstract
This paper presents a method for the detection of faults in electrical pumps. The method relies on the computation of two features, the pump efficiency and the hydraulic balance, that present reference values during healthy pump operation and change when the pump is affected by a fault. In this paper, the CUSUM Change Detection Test and the Mann-Whitney Change Point Method are proposed as change detection algorithms to process both features. The method has been applied to a real installation wit...
Citation
Soldevila, A., Blesa, J., Rosa M. Fernandez-Canti, Tornil-Sin, S., Meseguer, J., Puig, V. Pumps condition assessment in water distribution networks. "IFAC-PapersOnLine", 1 Gener 2018, vol. 51, núm. 24, p. 662-667.
Keywords
Fault detection water pumps
Group of research
CS2AC-UPC - Supervision, Safety and Automatic Control