Loading...
Loading...

Go to the content (press return)

Implementation of a piezo-diagnostics approach for damage detection based on PCA in a linux-based embedded platform

Author
Camacho, J.; Quintero, A.; Ruiz, M.; Villamizar, R.; Mujica, L.E.
Type of activity
Journal article
Journal
Sensors
Date of publication
2018-11-01
Volume
18
Number
11
First page
3730
Last page
3745
DOI
https://doi.org/10.3390/s18113730 Open in new window
Repository
http://hdl.handle.net/2117/125268 Open in new window
URL
https://www.mdpi.com/1424-8220/18/11/3730 Open in new window
Abstract
The implementation of damage-detection methods for continuously assessing structural integrity entails systems with attractive features such as storage capabilities, memory capacity, computational complexity and time-consuming processing. In this sense, embedded hardware platforms are a promising technology for developing integrated solutions in Structural Health Monitoring. In this paper, design, test, and specifications for a standalone inspection prototype are presented, which take advantage ...
Citation
Camacho-Navarro, J., Quintero, A., Ruiz, M., Villamizar, R., Mujica, L. Implementation of a piezo-diagnostics approach for damage detection based on PCA in a linux-based embedded platform. "Sensors", 1 Novembre 2018, vol. 18, núm. 11, p. 3730-3745.
Keywords
embedded system, guided waves, online monitoring, pipeline damage detection, principal component analysis, structural health monitoring