Robust high-order repetitive control of an active filter using an odd-harmonic internal model

Author
Ramos, G.A.; Costa-Castelló, R.; Olm, Josep M.; Cardoner, R.
Type of activity
Presentation of work at congresses
Name of edition
IEEE International Symposium on Industrial Electronics 2010
Date of publication
2010
Presentation's date
2010-07-07
Book of congress proceedings
Proceedings of the ISIE'10
First page
1040
Last page
1045
Repository
http://hdl.handle.net/2117/8432 Open in new window
URL
http://www.isie2010.it/ Open in new window
Abstract
Shunt active power filters have proven to be an efficient means to compensate for the negative effects of nonlinear and reactive loads on the power quality of the electrical distribution network. In this context, the control objective is to achieve a power factor close to 1, as well as load current harmonics and reactive power compensation. A useful control strategy for this purpose is repetitive control. However, the performance of repetitive controllers is strongly affected by frequency variat...
Citation
Ramos, G. [et al.]. Robust high-order repetitive control of an active filter using an odd-harmonic internal model. A: IEEE International Symposium on Industrial Electronics. "IEEE International Symposium on Industrial Electronics 2010". Bari: 2010, p. 1040-1045.
Group of research
ACES - Advanced Control of Energy Systems
CS2AC-UPC - Supervision, Safety and Automatic Control
SAC - Advanced Control Systems

Participants