Loading...
Loading...

Go to the content (press return)

Run to failure: aging of commercial battery cells beyond their end of life

Author
Andreas, Z.; Oeser, D.; Hein, T.; Montesinos-Miracle, D.; Ackva, A.
Type of activity
Journal article
Journal
Energies
Date of publication
2020-04-11
Volume
13
Number
8
First page
1858:1
Last page
1858:11
DOI
10.3390/en13081858
Repository
http://hdl.handle.net/2117/186958 Open in new window
URL
https://www.mdpi.com/1996-1073/13/8/1858 Open in new window
Abstract
The aim of this work is to age commercial battery cells far beyond their expected lifetime. There is a gap in the literature regarding run to failure tests of lithium-ion batteries that this work intends to address. Therefore, twenty new Samsung ICR18650-26F cells were aged as a battery pack in a run to failure test. Aging took place with a constant load current and a constant charge current to accelerate capacity decrease. Important aging parameters such as capacity and internal resistance were...
Citation
Andreas, Z. [et al.]. Run to failure: aging of commercial battery cells beyond their end of life. "Energies", 11 Abril 2020, vol. 13, núm. 8, p. 1858:1-1858:11.
Keywords
Aging, Computed tomography, Lithium-ion, Run to failure, battery
Group of research
CITCEA - Centre of Technological Innovation in Power Electronics and Drives

Participants